We offer advanced solutions for developing your business.

2K-DC LACK 70ST

2K-DC LACK 70ST
SKU: 10

Two component topcoat on acrylic resin basis, chemical cured with poly-isocyanate (polyurethane).

2K-Derocryl Lack 70 ST
Two component topcoat on acrylic resin basis, chemical cured with poly-isocyanate (polyurethane).

 

Field of application 

  • Corrosion protection for iron and steel.
  • Certified (180159 ILF), (180162 ILF), (200417 ILF) in the 2K-Deripox Protec ZP epoxy primer system for the C5 high category.
  • Good flow during processing in low pressure spray with hardener.

 

Properties

  • High solids content
  • Resistance to light acids
  • Resistance to weak bases
  • Coating systems for low temperatures
  • Good UV stability, the most resistant product in the sun!
  • Fast hardening
  • BIOBASED – product from raw material extracted from plants
  • Colors according to the RAL catalog
  • Quick drying
  •  Consumption 97.5-195 g/m2
  • Quality product made in Germany
  • Long term of exploitation in systems of up to 30 YEARS!

 

2K-DC LACK 70ST
Colours RAL 5010, RAL-colour chart with exceptions, apart from RAL 9006/9007.
Flash point >23 °C
Temperature stability -20 up to 120 (short-term up to 150) °C
Gloss Satin glossy, appr. 40 U in 60° angle
Potential dry film thickness in one working process 60 up to 120 µm
Mixing ratio Hardener HL 401 Hardener HL 115
(Basis:hardener) by weight 10:1 8:1
(Basis:hardener) by volume 7:1 5,3:1
Pot life in hours 2 2,5
Viscosity Thixotrope Appr. 30 sec running time (DIN 6 mm pot)
Density in kg/l 1,39 1,37
Solid content in % 72 71
Solid volume in % 57 55
Theoretical spreading capacity
  • 7,13 m²/l at 80 µm DFT
  • 5,13 m²/kg at 80 µm DFT
  • 6,88 m²/l at 80 µm DFT
  • 5,02 m²/kg at 80 µm DFT
Recommended film thickness 150 µm WFT corresponds to 90 µm DFT 150 µm WFT corresponds to 80 µm DFT
Drying (DIN EN ISO 1517) 80 µm DFT 80 µm DFT
Dust-dry (Tg1) After 30 min After 40 min
Touch-dry (Tg4) After 4 h After 5 h
Dry (Tg6) After 6 h After 6 h
Cured chemically After 7 days After 7 days
Accelerated drying 30 min. at 60°C possible, after 10 min. flash-off time 30 min. at 60°C possible, after 10 min. flash-off time
Interval for overcoating
  • after 8 h with itself
  • after 6 h with itself

Note

  • The specifications are related to the prepared mixture and are based on standard atmospheric conditions 23/50, DIN 50014.
  • Lower temperatures and/or higher humidity will prolong drying and hardening.
  • It is possible to use this material to limit frost temperature (possibly solvents are necessary).
Order a call